Termineter - Smart Meter Security Testing Framework
Many of these vulnerabilities have been highlighted by the media and advisories have been sent out by law enforcement agencies. The goal of a public release for this utility is to promote security awareness for Smart Meters and provide a tool that brings basic testing capabilities to the community and meter manufacturers so that security can be improved.
Power companies can use the framework to identify and validate internal flaws that leave them susceptible to fraud and significant vulnerabilities.
How it Works
Terminter utilises the C1218 and C1219 protocols for communication over an optical interface. Currently supported are Meters using C1219-2007 with 7-bit character sets.
This is the most common configuration found in North America. Termineter communicates with Smart Meters via a connection using an ANSI type-2 optical probe with a serial interface.
Users must have general knowledge of the meter’s internal workings in order to use Termineter proficiently.
Usage
termineter [-h] [-v] [-L {DEBUG,INFO,WARNING,ERROR,CRITICAL}] [-r RESOURCE_FILE]
-h, --help show this help message and exit
-v, --version show program's version number and exit
-L {DEBUG,INFO,WARNING,ERROR,CRITICAL}, --log {DEBUG,INFO,WARNING,ERROR,CRITICAL}
set the logging level
-r RESOURCE_FILE, --rc-file RESOURCE_FILE
execute a resource file
1
2
3
4
5
6
7
8
termineter [-h] [-v] [-L {DEBUG,INFO,WARNING,ERROR,CRITICAL}] [-r RESOURCE_FILE]
-h, --help show this help message and exit
-v, --version show program's version number and exit
-L {DEBUG,INFO,WARNING,ERROR,CRITICAL}, --log {DEBUG,INFO,WARNING,ERROR,CRITICAL}
set the logging level
-r RESOURCE_FILE, --rc-file RESOURCE_FILE
execute a resource file
Modules
brute_force_login – Brute Force Credentials
dump_tables – Dump Readable C12.19 Tables From The Device To A CSV File
enum_tables – Enumerate Readable C12.19 Tables From The Device
get_info – Get Basic Meter Information By Reading Tables
get_log_info – Get Information About The Meter’s Logs
get_modem_info – Get Information About The Integrated Modem
get_security_info – Get Information About The Meter’s Access Control
read_table – Read Data From A C12.19 Table
run_procedure – Initiate A Custom Procedure
set_meter_id – Set The Meter’s I.D.
set_meter_mode – Change the Meter’s Operating Mode
write_table – Write Data To A C12.19 Table
You can download Termineter here: